Kevin ALBS is a Three Phase inverter specially designed to handle the heavy surge current of electric motors.
Kevin ALBS –Automatic Lift Backup System, is a 3 phase DSP Sine Wave Inverter designed to generate 3 phase 4 wire OUT PUT to support Lift/Elevators during utility failure. In addition to this, important loads like staircase, parking, compound & common light, security system can be run through this innovative product. KEVIN ALBS is a unique combination of DSP SINE WAVE 3 phase inverter, storage, battery charger and an electronics change over module.
The charger is an isolated boost, converts to provide Constant Voltage & Constant Current. It charges the batterybank whenever the utility supply is available.
The Inverter provides 3 PHASE 4 WIRE regulated SINEWAVE to the lift and other related load, utilizing theenergy stored in Battery Bank. The inverter is customized to handle high inrush current capable of driving motor loads such as Elevators, Water Pumps, Fire Pumps etc.
Kevin ALBS offers comprehensive solution to most critical application & incorporates an array of outstanding user friendly features keeping in mind the day to day needs and long term technical and commercial .
4 KVA FOR 72 VDC
5 KVA FOR 96 V DC
6 KVA FOR 180 V DC
8 KVA FOR 180 V DC
10 KVA FOR 180V DC
12 KVA FPR 180 & 240 V DC
15 KVA FOR 276 & 360VDC
20 KVA FOR 360 VDC
25KVA FOR 360 VDC
30 KVA FOR 360 VD
Other Lift Inverter
Use Electro-Mechanical contactor which creates sparks, hence poor reliability & less life.
Low end Micro-controller based design, so the control is poor.
No Automatic load sensing.
Kevin ALBS
Use Solid State Static Switches. Almost zero failure.
High End DSP Based design. Fast control.
Automatic load sensing. Will stop in Door Open condition at the time of Low Battery Protection.
WHY ALBS IS BETTER THAN DG SET ???
KEVIN AUTOMATIC LIFT BACK UP SYSTEM
DG SET
Automatic Controlled
Manual Controlled
Low Capital Investment Per KVA
High Capital Cost Per KVA
No Extra Accessories
Additional Cost For Auto Changeover, AMF Panel, Acoustic Cover Etc.
Battery Power Utilizes Only Power Consumption When The Load Is Applied Is Less On Less Load .
Diesel Consumption Irrespective Of Load
Noiseless Operation
High Acoustic Noise
Environment Friendly
Air And Sound Pollution
Space Required Is Less
Relative Larger Area Required
Operational Cast Fix During The Battery Life Span
Variable On Account Of Fluctuating Fuel Cast
No Fuel Storage License Required
Fuel Storage License Required
Built In Protection Like Over Load, Short Circuit, Over Voltage, Regulated Voltage& Frequency
No Such Built In Protection As Standard Feature
Built In Emergency Landing Facility
Not Available
No Wear And Tear
High Wear And Tear
TECHNICAL SPECIFICATION
Rating
4 KVA To 40 KVA
Ac Input
415/230volt(+50/-90 Volt)
Input Power Factor
>=.9
Dc Voltage
72/69/120/180/276/360 Volt Dc
Charger Type
ASCI
Charging Time
10 Hours For 90% Full Battery Capacity
Inverter Technology
DSP Sine Wave
Out Put Voltage
400 Volt/230 Volt Per Phase
Inverter Efficiency
> 90%
Over Load
105% For 1 Hour
Harmonic Distortion
< 3%
Crest Factor
4:1
Power Factor
0.8
Phase Displacement
120º ±1º
Change Over Time
Inv To Mains Less Then 50msec Mains As To Inverter 3 Sec